Individual room temperature control
Features
The temperature is controlled independently and automatically for every room.
Automatic switching by weekly schedule, e.g. heating during the day and setback at night.
During holidays or with the heating switched off, the module protects against frost.
If a window or door contact stays open for longer, the temperature is lowered after a delay.
Display of the current phase: heating, setback, frost protection or off.
How the module works
The set temperature applies.
The setback temperature applies, e.g. at night – by weekly schedule or with an open window.
Frost protection is set. When deactivated, the previous values are restored.
Technical details: instance configuration 9 fields
| Settings instance (required) | Central instance used to control heating on/off and holiday mode. Without it the actuator module does not work correctly. |
|---|---|
| Actual temperature / sensor ID | Room temperature sensor for display (optional). |
| Set temperature / actuator ID | Target variable for the set temperature, e.g. a KNX thermostat. |
| Weekly schedule creation | No schedule or delete schedule, one group (Mon–Sun), two groups (Mon–Fri and Sat/Sun) or seven groups (per weekday). The times can then be adjusted. |
| Heating phase variable (optional) | Shows the active phase: heating, setback, frost protection or off. |
| Contact variable (optional) | Shows the window/door status: everything closed or at least one contact open. |
| Door and window contacts | Add the Boolean sensors. |
| Setback temperature (°C) | Target temperature for setback once the delay has expired. |
| Notification delay (seconds) | How long a contact must stay open continuously. Once all contacts are closed again, the module automatically returns to the active mode. |
Setup step by step 5 steps
- Set the set temperature – applies in the heating phase.
- Set the setback temperature – applies in the setback phase, e.g. at night.
- Use the weekly schedule for automatic switching between heating and setback.
- Activate holiday mode: frost protection is set; when deactivated, the previous values are restored.
- Window ventilation: with a window open, the temperature is lowered after the delay; when it is closed, the weekly schedule continues.
Frequently asked questions 2 questions
Why are the temperature controls greyed out?
The heating is probably switched off or holiday mode is active. In that case the system protects against frost and locks operation.
Why is there no control for “Setback”?
The setback control only appears when the weekly schedule is active.
We adapt modules – e.g. for additional sensors, bus systems or visualisations.